For the Replacement Battery please see Quick Find 240335. Features Intuitive LCD interface Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. High frequency design Reduces or eliminates bulky transformers resulting in lighter units for ease of handling. Auto recognition of external batteries UPS recognizes when external battery packs are attached and automatically adjusts runtime. Predictive replace battery date Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Energy meter Provides actual kilowatt hours of usage for energy conscious users. Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. Multiple switched outlet groups Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. Single switched outlet group Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. High online efficiency Reduces utlility costs, generates less heat. EPO Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emergency situation. SmartSlot Customize UPS capabilities with management cards. Cold-start capable Provides temporary battery power when the utility power is out. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Scalable runtime Allows additional run time to be quickly added as needed. Rack/Tower convertible Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. Availability Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Disconnected battery notification Warns when a battery is not available to provide backup power. Manageability Network manageable Provides remote power management of the UPS over the network. Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. LED status indicators Quickly understand unit and power status with visual indicators. Serial Connectivity Provides management of the UPS via a serial port. USB connectivity Provides management of the UPS via a USB port (not available on all models). Disconnected battery notification Warns when a battery is not available to provide backup power. Serviceability User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Adaptability Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Safety Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Includes: CD with software, Documentation CD, Installation guide, Removable support feet, Smart UPS signalling RS-232 cable, User Manual Please note: networking components such as switches, routers, UPS and wireless devices require that speeds & standards be consistent throughout the network to gain optimum performance. To avoid compatibility clashes or for advice, please contact us on solutions@ebuyer.com.